If your generator has suddenly stopped working or refuses to start, the Generac generator error codes it gives you can help you figure out what might be wrong. These codes appear anytime your generator detects an issue and can almost always tell you exactly what is wrong.
Finding out that your generator isn’t working properly is always an inconvenience, but the good news is that not every error code means your generator needs expensive repairs. In fact, many of the most common problems can be solved with basic troubleshooting.
Still, some error codes will require professional attention to resolve. So, if your Generac generator is displaying an unfamiliar code, here’s what you need to know about what it means and how to get your backup power system working again.
What Do Generac Generator Error Codes Mean?
Generac standby generators come equipped with onboard controllers that monitor the system’s performance. When something goes wrong, this controller will display an error code and automatically shut down the generator to prevent further damage.
Each error code corresponds to a particular operating issue, which makes it much easier to narrow down what might be causing the problem. However, just because your generator displays a particular code doesn’t necessarily mean you’ll know exactly what’s causing it.
There are plenty of different issues that can trigger the same warning, so it’s always best to consult your owner’s manual or a professional before attempting any troubleshooting.
What Are the Most Common Generac Generator Error Codes?
There are dozens of potential error codes that your Generac generator might display, depending on its model and controller. But some are more common than others, and understanding what they mean can help you decide what to do next.
Here are five error codes you should know about.
Error Code 1100: Overcrank
Error code 1100 means your generator has attempted to start but couldn’t successfully get the engine running within its programmed starting limits.
This can happen for several reasons, including having an insufficient fuel supply, experiencing ignition problems, or the presence of some other engine-related issue.
If you encounter this code, start by checking whether your home’s fuel supply is available. If nothing seems out of place, and your gas connection seems to be working, you’ll likely need professional help to diagnose the problem and get your generator running again.
Error Code 1300: Low Oil Pressure
Your generator needs adequate oil pressure to keep its engine sufficiently lubricated, and if the system detects that the oil pressure has dropped below acceptable levels, it will display error code 1300 and shut down.
Low oil levels, oil leaks, and faulty pressure sensors are all potential causes, and you can most likely confirm this by checking the oil level according to your owner’s manual. But if the oil level is normal or the warning continues after adding more oil, you should contact a generator professional before attempting any more restarts.
Error Code 1400: High Temperature
Error code 1400 indicates that your generator has exceeded safe operating temperatures.
Generators produce a considerable amount of heat during operation, but their built-in cooling systems normally have no problem keeping them at a reasonable temperature. However, all it takes is blocked ventilation, accumulated debris, or some other cooling-system problem to make the generator overheat.
If this code appears, the first thing you need to do is let it cool down before checking for and removing anything that may be preventing proper ventilation. If you can’t identify an obvious problem, it’s best to have the cooling system professionally inspected before running the generator again.
Error Code 1505: RPM Sense Loss
If your generator displays error code 1505, it means that the controller hasn’t detected the expected engine-speed signal during startup.
This could mean that the sensor itself is malfunctioning, but it could also mean that a weak battery, fuel supply problem, or other engine-related issue is actively preventing the generator from starting properly.
Because there is a wide variety of different problems that can produce this code, there isn’t really much troubleshooting you can do, and you’ll almost certainly need to call a professional to perform proper diagnostic testing.
Error Code 2800: Auxiliary Shutdown
Error code 2800 usually means one of your generator’s auxiliary shutdown switches has been activated. These switches simply turn the generator off and are normally used when performing routine maintenance or during an emergency. However, it’s not uncommon for people to activate them accidentally.
If you see this code, all you need to do is consult your owner’s manual to locate the shutdown switches so you can flip them back on. But if the switches are in their normal positions and the warning persists, you’ll probably need a professional technician to inspect the switches and connecting wiring.
Can Regular Maintenance Help Prevent Generator Error Codes?
Yes, regular maintenance can help reduce the likelihood of all sorts of different generator problems, especially when it comes to oil levels, aging batteries, dirty filters, and general engine wear.
Though maintenance can’t prevent every possible issue, keeping up with your generator’s service schedule can help you catch developing problems before they leave you without backup power.
For more information, check out our guide to preventing common generator problems with regular maintenance.
When Should You Call a Professional for Generator Error Codes?
If your generator keeps shutting down, repeatedly fails to start, shows a code that requires professional attention from the start, or simply continues to display the same warnings even after you’ve done your basic troubleshooting, it’s time to call a professional.
At New London Electric, we’ve been helping homeowners all throughout Southern Chester County and Northern Delaware with their electrical and generator installation needs since 1994. We know how annoying generator issues can be, but no matter what generator error codes you’re seeing, you can always trust our team to get it back up and running again in no time.
Contact New London Electric Today
Are you dealing with a Generac generator that won’t start or keeps displaying confusing error codes? Give us a call.
Our experienced team is happy to answer your questions and discuss how we may be able to help with your generator concerns. We even offer free project estimates and can help you determine the best next steps for your backup power needs.
Don’t wait until the next power outage to address a problem with your generator. Contact New London Electric today.